A range by ETS Europe, Belgium.
Hypertectum
Contact
Liquid Membrane

Hypertectum AF

Aliphatic PU finishing coat, white or light grey. UV-resistant.

Use it forRoofs, balconies and verandas, tiles, concrete, asphalt and EPDM membranes, light metal or fibre-cement roofing, car parks, tanks (not drinking water).
Apply withBrush, roller or airless spray
Curing timeTack-free: 6 h at 25 °C. Recoat: 6–24 h.
Coverage0.8-0.9 kg/m²

Introduction

Hypertectum AF is a one-component aliphatic polyurethane membrane that cures with atmospheric humidity. It forms a highly elastic, durable, UV-resistant layer with strong adhesion to many surfaces when the correct primer is used. It is applied in two coats: AF as the first coat and AF as the finishing coat.

Technical properties

Hypertectum AF · See the technical data sheet for test conditions and full specifications.
PropertyValue
Elongation at break (23 °C)> 600 %
Elongation at −25 °C450 %
Service temperature-40 to +80 °C
Hardness70 Shore A
Tensile strength at 23 °C55 kg/cm² (5.5 N/mm²)
Adhesion to concrete> 2 N/mm²
Water vapour transmission0.8 g/m²·h
Density1.3–1.4 g/cm³

System build-up

  1. 01Substrate
  2. 02primer from the Hypertectum range
  3. 03Hypertectum AF as the first coat
  4. 04Hypertectum AF as the second coat

The sheet lists a minimum total consumption of 1.5–1.8 kg/m² for both coats.

Hypertectum AF — full specification

Before you start

Clean with high pressure; remove oil, grease, wax, loose concrete skin and curing compounds. Repair defects in old roofs and make sure there is no moisture beneath. Then apply the correct primer for the substrate.

The surface must be dry. Ideal temperature is 16 °C; ambient temperature must always be above 5 °C.

Application

Mix with a low-speed mixer. For airless spraying, up to 5–10% X-cleaner can be added. Apply by roller, brush or airless spray.

Do not exceed 48 hours between coats. If more than 4 days pass, a new primer must be applied.

Where it goes

Tiles, plaster and concrete, bathrooms, verandas and balconies, roofs, asphalt membranes, tanks (not for drinking water), irrigation channels, car parks and stadium stands, EPDM membranes, bridge platforms, light metal or fibre-cement roofing.

Cleaning and storage

Clean tools with ETS X-cleaner. Apply in well-ventilated areas away from naked flames; consult the safety data sheet.

Pack sizes: 1, 6, 15, 25 and 200 kg. At least 12 months in unopened pails in a dry place above 5 °C; use as soon as possible once opened.